| Rated power |
8000W |
10000W |
12000W |
| BATTERY INPUT DATA |
| Battery type |
Lead-acid battery / Lithium battery |
| Battery voltage |
48V |
| Battery voltage range |
40~60V |
| Charging curve |
3-stage adaptive with maintenance/Equalization |
| Charging Strategy for Li-lon Battery |
Self-adaption to BMS |
| Over-current protection/ Over-temperature protection |
Yes / Yes |
| Maximum charging/discharging power |
8000W |
10000W |
1000W |
| Maximum charging/discharging current |
190A |
210A |
240A |
| PV STRING INPUT DATA |
| Max. DC Input Power |
12000W |
15000W |
18000W |
| Rated PV Input Voltage |
550V |
| Maximum DC voltage |
800V |
| Start-up Voltage |
160V |
| Minimum voltage for grid connection |
310V |
| Full Load DC Voltage Range |
350-650V |
| Enter high voltage error recovery point |
800V |
| MPPT voltage range |
200~650V |
| Maximum input current |
15A/15A |
26A/13A |
| No.of MPP Trackers |
2 |
| No.of Strings per MPP Tracker |
1+1 |
2+1 |
| AC OUTPUT DATA |
| Rated AC Output Power |
8000W |
10000W |
12000W |
| Max AC Output Power |
8800W |
11000W |
13200W |
| AC Output Rated Current |
12.1/11.6A |
15.2/14.5A |
18.2/17.4A |
| Max AC Output Current |
13.4/12.8A |
16.7/15.9A |
20/19.1A |
| Max. Three-phase Unbalanced Output Current |
18.2/17.4A |
22.7/21.7A |
27.3/26.1A |
| Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage |
220/380,230/400Vac |
| Rated Input/Output Grid Frequency/Range |
50/60;45~55/55-65 |
| Grid Type |
Three Phase |
| Total Harmonics Current Distortion (THDi) |
<3% (of nominal power) |
| DC Current Injection |
<0.5% In |
| EFFICIENCY |
|
≥97.5% |
|
97.0% |
| PROTECTION |
| Integrated |
PV Arc Fault Detection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection |
| Surge Protection |
DC Type III/AC Type III |
| Overvoltage Category |
DC Type II/AC Type III |
| GENERAL DATA |
| Operating Temperature Range (°C) |
-20°C to +60°C, >45°C Derating |
| Cooling |
Smart cooling |
| Noise (dB) |
≤55dB |
| Communication with BMS |
Wi-Fi/USB/GPRS/RS485/CAN |
| Machine Dimension (W*H*D)(mm) |
444*654.2*259.2 |
| Package Dimension (W*H*D)(mm) |
816*404*567 |
| N.W(kg) |
35 |
| G.W(kg) |
37 |
| Protection Degree |
IP65 |
| Installation Style |
Wall-mounted |
| Warranty |
5 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |