Out of stock
₨12,500.00 ₨14,000.00
Out of stock
Compare



| MODEL | MP-MAGNUM-DUAL 3.5KW | MP-MAGNUM-DUAL 5.5KW |
|---|---|---|
| Nominal Battery System Voltage | 24VDC | 48VDC |
| INVERTER OUTPUT | ||
| Rated Power (Main+Second Load) | 3500VA/3500W | 5500VA/5500W |
| Surge Power | 7000W | 11000W |
| Waveform | Pure sine wave | |
| AC Voltage Regulation (Batt.Mode) | 230VAC±5%(Setting) | |
| 90~93% | ||
| Transfer Time | 10ms (UPS / VDE4105) / 20ms (APL) | |
| AC INPUT | ||
| Voltage | 230VAC±5% | |
| Selectable Voltage Range | 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105) | |
| Frequency Range | 50Hz / 60Hz(Auto sensing) | |
| BATTERY | ||
| Normal voltage | 24VDC | 48VDC |
| Floating Charge Voltage | 27.4VDC | 54.8VDC |
| Overcharge Protection | 30VDC | 60VDC |
| SOLAR CHARGER &AC CHARGER | ||
| Maximum PV Array Open Circuit Voltage | 450VDC | 450VDC |
| Maximum PV Input Current | 18A | 28A |
| Charging Algorithm | 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li) | |
| Maximum PV Array Power | 4200W | 6200W |
| PV Array MPPT Voltage Range(Typ.) | 60~360VDC | |
| Maximum Solar Charge Current | 100A | |
| Maximum AC Charge Current | 60A | 100A |
| Maximum Charge Current | 100A | |
| MECHANICAL SPECIFICATIONS | ||
| Machine Dimension (W*H*D) | 367*318*122.5mm | 454*318*122.5mm |
| Package Dimension (W*H*D) | 459*410*200mm | 544.5*410*200mm |
| N.W (kg) | 7.2kg | 9.0kg |
| G.W (kg) | 8.2kg | 10.5kg |
| OTHER | ||
| Humidity | 5% to 95% Relative humidity (Non-condensing) | |
| Operating Temperature | 0°C~50°C | |
| Storage Temperature | -15°C~60°C | |
| MODEL | MP-MAGNUM-DUAL 3.5KW | MP-MAGNUM-DUAL 5.5KW |
|---|---|---|
| Nominal Battery System Voltage | 24VDC | 48VDC |
| INVERTER OUTPUT | ||
| Rated Power (Main+Second Load) | 3500VA/3500W | 5500VA/5500W |
| Surge Power | 7000W | 11000W |
| Waveform | Pure sine wave | |
| AC Voltage Regulation (Batt.Mode) | 230VAC±5%(Setting) | |
| 90~93% | ||
| Transfer Time | 10ms (UPS / VDE4105) / 20ms (APL) | |
| AC INPUT | ||
| Voltage | 230VAC±5% | |
| Selectable Voltage Range | 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VED4105) | |
| Frequency Range | 50Hz / 60Hz(Auto sensing) | |
| BATTERY | ||
| Normal voltage | 24VDC | 48VDC |
| Floating Charge Voltage | 27.4VDC | 54.8VDC |
| Overcharge Protection | 30VDC | 60VDC |
| SOLAR CHARGER &AC CHARGER | ||
| Maximum PV Array Open Circuit Voltage | 450VDC | 450VDC |
| Maximum PV Input Current | 18A | 28A |
| Charging Algorithm | 3-Step (Flooded Battery, AGM / GEL / LEAD Battery), 4-Step (Li) | |
| Maximum PV Array Power | 4200W | 6200W |
| PV Array MPPT Voltage Range(Typ.) | 60~360VDC | |
| Maximum Solar Charge Current | 100A | |
| Maximum AC Charge Current | 60A | 100A |
| Maximum Charge Current | 100A | |
| MECHANICAL SPECIFICATIONS | ||
| Machine Dimension (W*H*D) | 367*318*122.5mm | 454*318*122.5mm |
| Package Dimension (W*H*D) | 459*410*200mm | 544.5*410*200mm |
| N.W (kg) | 7.2kg | 9.0kg |
| G.W (kg) | 8.2kg | 10.5kg |
| OTHER | ||
| Humidity | 5% to 95% Relative humidity (Non-condensing) | |
| Operating Temperature | 0°C~50°C | |
| Storage Temperature | -15°C~60°C | |
| Rated power | 8000W | 10000W | 12000W | |
|---|---|---|---|---|
| Rated power | 8000W | 10000W | 12000W | |
| BATTERY INPUT DATA | ||||
| Battery type | Lead-acid battery / Lithium battery | |||
| Battery voltage | 48V | |||
| Battery voltage range | 40~60V | |||
| Charging curve | 3-stage adaptive with maintenance/Equalization | |||
| Charging Strategy for Li-lon Battery | Self-adaption to BMS | |||
| Over-current protection/ Over-temperature protection | Yes / Yes | |||
| Maximum charging/discharging power | 8000W | 10000W | 1000W | |
| Maximum charging/discharging current | 190A | 210A | 240A | |
| PV STRING INPUT DATA | ||||
| Max. DC Input Power | 12000W | 15000W | 18000W | |
| Rated PV Input Voltage | 550V | |||
| Maximum DC voltage | 800V | |||
| Start-up Voltage | 160V | |||
| Minimum voltage for grid connection | 310V | |||
| Full Load DC Voltage Range | 350-650V | |||
| Enter high voltage error recovery point | 800V | |||
| MPPT voltage range | 200~650V | |||
| Maximum input current | 15A/15A | 26A/13A | ||
| No.of MPP Trackers | 2 | |||
| No.of Strings per MPP Tracker | 1+1 | 2+1 | ||
| AC OUTPUT DATA | ||||
| Rated AC Output Power | 8000W | 10000W | 12000W | |
| Max AC Output Power | 8800W | 11000W | 13200W | |
| AC Output Rated Current | 12.1/11.6A | 15.2/14.5A | 18.2/17.4A | |
| Max AC Output Current | 13.4/12.8A | 16.7/15.9A | 20/19.1A | |
| Max. Three-phase Unbalanced Output Current | 18.2/17.4A | 22.7/21.7A | 27.3/26.1A | |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
| Rated Input/Output Voltage | 220/380,230/400Vac | |||
| Rated Input/Output Grid Frequency/Range | 50/60;45~55/55-65 | |||
| Grid Type | Three Phase | |||
| Total Harmonics Current Distortion (THDi) | <3% (of nominal power) | |||
| DC Current Injection | <0.5% In | |||
| EFFICIENCY | ||||
| ≥97.5% | ||||
| 97.0% | ||||
| PROTECTION | ||||
| Integrated | PV Arc Fault Detection, Anti-islanding Protection, PV String Input Reverse Polarity Protection,Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection | |||
| Surge Protection | DC Type III/AC Type III | |||
| Overvoltage Category | DC Type II/AC Type III | |||
| GENERAL DATA | ||||
| Operating Temperature Range (°C) | -20°C to +60°C, >45°C Derating | |||
| Cooling | Smart cooling | |||
| Noise (dB) | ≤55dB | |||
| Communication with BMS | Wi-Fi/USB/GPRS/RS485/CAN | |||
| Machine Dimension (W*H*D)(mm) | 444*654.2*259.2 | |||
| Package Dimension (W*H*D)(mm) | 816*404*567 | |||
| N.W(kg) | 35 | |||
| G.W(kg) | 37 | |||
| Protection Degree | IP65 | |||
| Installation Style | Wall-mounted | |||
| Warranty | 5 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
|||
Select at least 2 products
to compare







There are no reviews yet.